This template has been created with Zabbix v5.4.12 but should also be usable for other versions of Zabbix with a few changes.

OVERVIEW
- Templates available for Expert Power Control-Series, Expert Sensor Box-Series, Expert Net Control-Series
- Templates are used for easy integration into Zabbix
- Sensors such as power consumption, electrical currents, power port status & environment data (temperature, humidity, air pressure) can be monitored
- For support & questions please contact: support@gude-systems.com

MACROS
- There are no macros used in the templates

DISCOVERY RULES
- There are no discovery rules used in the templates

TRIGGERS
- There are no triggers used in the templates

ITEMS
- Items in the templates use SNMP for sensor monitoring

Following items can be monitored:
- Some features might only be available for certain product lines

Bank: Voltage AC rms (V) (Voltage in V on power channel)
Bank: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current in A on power channel)
Bank: Power active (W) (Active power in W on power channel)
Bank: Power reactive (VAR) (Reactive power in VAR on power channel)
Bank: Power apparent (VA) (Apparent power in VA on power channel)
Bank: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power channel)
Bank: Residual Current Type A (mA) (Multiplier: 1/1000) (Residual current type A in mA on power channel)
Bank: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power channel)

Power Port 1-12: Status (Status of power port 1-12, 0 = off, 1 = on)
Power Port 1-12: Voltage AC rms (V)(Voltage in V on power port 1-12)
Power Port 1-12: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current on in A power port 1-12)
Power Port 1-12: Power active (W) (Active power in W on power port 1-12)
Power Port 1-12: Power reactive (VAR) (Reactive power in VAR on power port 1-12)
Power Port 1-12: Power apparent (VA) (Apparent power in VA on power port 1-12)
Power Port 1-12: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power port 1-12)
Power Port 1-12: Residual Current Type A (mA) (Residual current type A in mA on power port 1-12)
Power Port 1-12: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power port 1-12)

Input 1-12: Status (Status of input port 1-12, off/on)

Sensor 1: Temperature (°C) (Multiplier: 1/10)
Sensor 1: Humidity (%) (Multiplier: 1/10)
Sensor 1: Air pressure (hPa)
Sensor 2: Temperature (°C) (Multiplier: 1/10)
Sensor 2: Humidity (%) (Multiplier: 1/10)
Sensor 2: Air pressure (hPa)
Sensor 3: Temperature (°C) (Multiplier: 1/10)
Sensor 3: Humidity (%) (Multiplier: 1/10)
Sensor 3: Air pressure (hPa)
Sensor 4: Temperature (°C) (Multiplier: 1/10)
Sensor 4: Humidity (%) (Multiplier: 1/10)
Sensor 4: Air pressure (hPa)

- Applicable for products with two banks
Bank A: Voltage AC rms (V) (Voltage in V on power channel A)
Bank A: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current in A on power channel A)
Bank A: Power active (W) (Active power in W on power channel A)
Bank A: Power reactive (VAR) (Reactive power in VAR on power channel A)
Bank A: Power apparent (VA) (Apparent power in VA on power channel A)
Bank A: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power channel A)
Bank A: Residual Current Type A (mA) (Multiplier: 1/1000) (Residual current type A in mA on power channel A)
Bank A: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power channel A)

- Applicable for products with two banks
Power Port A1-6: Status (Status of power port A1-6, 0 = off, 1 = on)
Power Port A1-6: Voltage AC rms (V)(Voltage in V on power port A1-6)
Power Port A1-6: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current in A on power port A1-6)
Power Port A1-6: Power active (W) (Active power in W on power port A1-6)
Power Port A1-6: Power reactive (VAR) (Reactive power in VAR on power port A1-6 in)
Power Port A1-6: Power apparent (VA) (Apparent power in VA on power port A1-6)
Power Port A1-6: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power port A1-6)
Power Port A1-6: Residual Current Type A (mA) (Multiplier: 1/1000) (Residual current type A in mA on power port A1-6)
Power Port A1-6: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power port A1-6)

- Applicable for products with two banks
Bank B: Voltage AC rms (V) (Voltage in V on power channel B)
Bank B: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current in A on power channel B)
Bank B: Power active (W) (Active power in W on power channel B)
Bank B: Power reactive (VAR) (Reactive power in VAR on power channel B)
Bank B: Power apparent (VA) (Apparent power in VA on power channel)
Bank B: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power channel B)
Bank B: Residual Current Type A (mA) (Multiplier: 1/1000) (Residual current type A in mA on power channel B)
Bank B: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power channel B)

- Applicable for products with two banks
Power Port B1-6: Status (Status of power port B1-6, 0 = off, 1 = on)
Power Port B1-6: Voltage AC rms (V)(Voltage in V on power port B1-6)
Power Port B1-6: Current AC rms (A, max. 16A) (Multiplier: 1/1000) (Current in A on power port B1-6)
Power Port B1-6: Power active (W) (Active power in W on power port B1-6)
Power Port B1-6: Power reactive (VAR) (Reactive power in VAR on power port B1-6 in)
Power Port B1-6: Power apparent (VA) (Apparent power in VA on power port B1-6)
Power Port B1-6: Power factor (PF) (Multiplier: 1/1000) (Power factor between -1.0 and 1.0 on power port B1-6)
Power Port B1-6: Residual Current Type A (mA) (Multiplier: 1/1000) (Residual current type A in mA on power port B1-6)
Power Port B1-6: Total energy (kWh) (Multiplier: 1/1000) (Total energy in kWh on power port B1-6)

Author
David Chang

Latest